Tonnage | 2,000 T | 1,814.372 t |
Stroke | 72" | 1,828.8 mm |
Shut Height | 12" | 304.8 mm |
Bed area (Left to right) | 120" | 3,048 mm |
Bed area (Front to back) | 96" | 2,438.4 mm |
Daylight | 84" | 2,133.6 mm |
Fast Closing Speed | 1,000 in/min. | 2,540 cm/min. |
Pressing Speed | 55 in/min. | 139.7 cm/min. |
Stripping Speed | 200 in/min. | 508 cm/min. |
Fast Return Speed | 600 in/min. | 1,524 cm/min. |
CAPACITY
Pressing: 200 - 2000
Stripping: 18 - 180
Net Lift @ Fast Open: 40
DIMENSIONS
Daylight (between face of slide and bed bolster): 84
Stroke: 72
Shut Height: 12
Die Area: 120 x 96
Bed Bolster (right to left x front to back x thickness): 120 x 96 x 4
Between Columns (right to left x front to back): 122
Floor to Face of Bolster: 18
Overall Height: 320
Depth Below Floor: 48
OPERATING SPEEDS
Fast Close: 1000
Slow Close: 2000
Fast Pressing (up to 1200 tons): 20 - 55
Pressing (to 2000 tons): 2 - 35
Stripping: 20 - 200
Fast Open: 600
DATE ISSUED: 12 - 22 - 00
DESCRIPTION: 2000-Ton 4-Column Hydraulic Press
AUXILIARY SYSTEM
Quantity & Type: (8) Size DO5 4-Way Valves
Location: (6) On Press Bed, (2) On Press Slide
Core/Eject Valves: (2) On the right side of the press bed and (2) on the right side of the press slide programmable as cores or ejector
Die Gate Valves: (4) On the right side of the press bed controlled by the customer controlled inputs. See electrical specifications for valve function.
Oil Cooling System: Water/Oil cooling system complete with strainer, on/off solenoid operated control valve, temperature actuated water modulating valve and stainless steel braze pak type heat exchanger
Oil Cooling Customer Connections: Connections from ceiling
Oil Filtration System: Continuous low pressure off line kidney loop filtration with on line pressure filtration of pump control pilot system.
Press System Tonnage Control: Electronic (Vickers KACG)
PREFILL VALVE
Quantity & Type: (3) Olmsted #PRT-0708
Hydraulic Component Usage: REXROTH / VICKERS
Components Power Connection: DIN plug in style with lights
Pipe Connections: SAE 4-Bolt Buttweld Flanges
Tube Connections: Parker Seal-LOK
Diagnostic Fittings: Stauff TCM Series
ELECTRICAL SERVICE: 575 V / 3 Phase / 60 Hertz
We use cookies to improve your experience. Privacy Policy.
We use different type of cookies to optimize your experience on our website. You may choose which type of cookies to allow and can change your preferences at any time. Remember that disabling cookies may affect your experience on the website. You can learn more about how we cookies by visiting our Privacy Policy.
These cookies are necessary to the core functionality our website and some of its features, such as access to secure areas.
These cookies are used to enhance the performance and functionality of our website but are nonessential. However, without these cookies, certain functionality may become unavailable.
These cookies gather information to help us understand site usage, measure marketing effectiveness, and personalize your experience.
These cookies enhance ad relevance, prevent repeat ads, ensure proper display, and sometimes tailor ads to your interests.